La Crosse WS2355 Specifications
Outdoor Data
Transmission distance in Open Field: 100 metres max.
Temperature range : -29.9° C to +699° C (shows “OFL” if outside range)
Resolution : 0.1° C
Measuring range relative humidity : 10% to 99%
Rain volume display : 0 to 999.9 mm (1 hour and 24 hour rainfall), 0 to 2499.9 mm (Total rainfall)
Resolution : 0.1 mm
Wind speed : 0 to 180 km/h or 0 to 50 m/s
Resolution : 0.1 m/s
Wind direction : Graphic Resolution 22.5 Degrees, Numerical Resolution Letter format
Data Transmission
Wireless 433 MHz data transmission: Measuring Interval thermo-hygro sensor : 32 seconds (if wind speed>10m/s) or 128 seconds (if wind speed<10m/s). 10 minutes (if the base station fails to receive any data after 5 attempts in a row; all outdoor data readings will display “---“ except for the rain value)
With wire data transmission: Measuring interval thermo-hygro sensor : 8 seconds
Indoor Data
Pressure/temperature checking interval : 4 times per minute
Indoor temperature range : -9.9° C to + 59.9° C (shows “OFL” if outside range)
Resolution : 0.1° C
Measuring range relative humidity : 1 % to 99 %
Resolution : 1%
Relative humidity checking interval : 3 times per minute
Measuring range air pressure : 760 hPa to 1099 hPa (Standard air pressure at an altitude of 2,300 metres is around 760 hPa)
Resolution : 0.1 hPa
[ back ]